ATTENTION
This appliances can be installed and used only on permanently ventilated
premises in accordance with the standards.
- Installation premises
To ensure the gas-run appliance works properly the room in which it is installed
must have enough air for the combustion gas, in compliance with the current
standards. Vents with a minimum section of at least 100 cm², must be made so
they cannot be obstructed either from indoors or outdoors and located close to
the floor Fig.9; any other type of ventilation must necessarily comply with the
contents of the standard.
- Fumes discharge
Gas-run appliances must discharge the products of combustion directly outdoors
through a flue, suction hood or electric at a flow rate that will guarantee an hourly
change of air that is at least 3 times the volume of the room. Remember that the
air necessary for combustion is 2m
3
/h for each kW of nominal heat capacity (see
rating plate).
AIR INLET 100