20
Table for the Choice of the Injectors
GB
Cat: II 2H3+
Burners
Nominal
Power
kW
Reduced
Power
kW
G30 - 28-30 mbar
G31 - 37 mbar
G20 - 20 mbar
Ø Injector
1/100 mm
Ø Injector
1/100 mm
Auxiliary (A) 1,00 0,30 50 72 (X)
Semi-Rapid (SR) 1,75 0,45 65 97 (Z)
Rapid (R) 3,00 0,75 85 115 (Y)
Triple Ring (TR) 3,50 1,50 95 135 (T)
Lubrication of the Gas Taps
The operations must be executed by a qualied technician.
IMPORTANT: All intervention regarding installation maintenance and conversion of the applian-
ce must be fullled with original factory parts.
The manufacturer declines any liability resulting from the non-compliance of this obligation.