55
Green & Yellow
(Earth)
Brown (Live)
Blue (Neutral)
N
L
Fig. 9.1
Fig. 9.2
WARNING: This appliance must be earthed
A
C
P
D
B
CONNECTING THE DOUBLE OVEN MAINS CABLE
Unscrew the screw A securing the cover plate B behind the oven (fig. 9.1).
Remove the cover plate B.
Remove the screws C from the cable clamp (fig. 9.2).
Insert the mains cable (type H05RR-F or H05VV-F - 3x2,5 mm
2
section) into the
cable protector P.
Connect the phase and earth cables to the mains terminal connection block D.
EARTH
N NEUTRAL
L LIVE
Refit the cable clamp so that it clamps the outer sleeving of the cable, and screw
the screws C.
Refit the cover plate B and fix it with the screw A.