CDA ci860 Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Pralko-suszarki CDA ci860. 7 - Fieldbus Foundation Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - DCS and Fieldbus Foundation

DCS and Fieldbus Foundation Shivaji Day Process Automation, ABB ABB

Strona 2 - - Subsystem Integration

© 1994 – 2011 Fieldbus Foundation 12 Foundation Fieldbus with 800xA ABB

Strona 3 - OSI Model

© 1994 – 2011 Fieldbus Foundation 13 800xA – DCS with integrated FF High availability means redundancy at all levels:  System servers and workplaces

Strona 4 - Fieldbus Network

© 1994 – 2011 Fieldbus Foundation 14 Foundation Fieldbus redundancy Redundant Linking device FF HSE HSE / H1 Linking Device Multi Barrier Multi Barri

Strona 5 - Control

© 1994 – 2011 Fieldbus Foundation 15 FF Device Integration FF is an integrated architecture for distribution of control applications Two different fie

Strona 6 - Segment 1

© 1994 – 2011 Fieldbus Foundation 16 Fieldbus Builder Foundation Fieldbus Fieldbus Builder FF performs the configuration and commissioning of FF netwo

Strona 7 - FOUNDATION H1

© 1994 – 2011 Fieldbus Foundation 17 FF Device Integration Library (1) Library contents: FF Block Library with FF standard blocks and device specific

Strona 8

© 1994 – 2011 Fieldbus Foundation 18 FF Device Integration Library (2) Asset monitoring Asset tree viewer Asset reporter Asset alarms / notification M

Strona 9 - Capability File

© 1994 – 2011 Fieldbus Foundation 19 FF Faceplates  Header: display of process tag and its description  Indicator bar: display of function block sta

Strona 10 - Foundation Fieldbus

© 1994 – 2011 Fieldbus Foundation 20 FF System Structure AC 800M FF HSE Link FF H1 Links Pub/Sub Pub/Sub HSE Linking Device FF HSE Link FF H1 Links P

Strona 11 - High availability means

© 1994 – 2011 Fieldbus Foundation 21 FF HSE application H1 link A OUT AI PID BK_CAL IN OUT IN H1 link B OUT AI PID BK_CAL IN OUT IN CAS_ IN CAS_IN AO

Strona 12 - Ethernet TPC/IP

© 1994 – 2011 Fieldbus Foundation 3 © ABB July 17, 2012 | 3  FOUNDATION Fieldbus HSE - Server Integration - HSE is the “Open Common” interface for

Strona 13 - HSE Subnet with 100 Mbit/s

© 1994 – 2011 Fieldbus Foundation 22 FF Parameter Displays Display and operation of block parameter All parameters listed  Predefined tabs for the

Strona 14 - Builder Foundation Fieldbus

© 1994 – 2011 Fieldbus Foundation 23 FF Network Components Device 1 Device 2 Device n Spur Blocks Power Supply Power Conditioner H1 Link HSE Subnet Re

Strona 15

© 1994 – 2011 Fieldbus Foundation 24 Foundation Fieldbus Basic Layout Max. 4000 devices per connectivity server (application dependent) Max. 30 Linkin

Strona 16 - Latest Device List at

© 1994 – 2011 Fieldbus Foundation 26 FF Installation - References ABB

Strona 17 - FF Faceplates

© 1994 – 2011 Fieldbus Foundation 27 • Client  The Reliance Group, is India's largest private sector enterprise, with businesses in the energy

Strona 18 - FF System Structure

© 1994 – 2011 Fieldbus Foundation 28 • Client  Jindal Steel West(JSW) Limited, are Specialized manufacturer and supplier of Steel Products.  JSW g

Strona 19 - FF HSE application

© 1994 – 2011 Fieldbus Foundation 29 References for Foundation Fieldbus installation 1 Tata Steel, Jamshedpur Sinter Plant#3 5000 IO on Profibus, 7OS

Strona 20 - FF Parameter Displays

© 1994 – 2011 Fieldbus Foundation 30 THANKS

Strona 21 - FF Network Components

© 1994 – 2011 Fieldbus Foundation 4 © ABB | 4 H1/HSE PHYSICAL LAYER 1 2 3 4 5 6 7 USER LAYER COMMUNICATION STACK H1 HSE H1 PHY @ 31.25 kbit/s H1

Strona 22 - • max 500 for discrete input

© 1994 – 2011 Fieldbus Foundation 5 © ABB July 17, 2012 | 5 Ethernet / IEEE 802 / FO FOUNDATION Fieldbus HSE OPC Server Ethernet TCP/IP IEC 61158-2 E

Strona 23 - FF Installation - References

© 1994 – 2011 Fieldbus Foundation 6 © ABB | 6 100 Mbit/s FF HSE HSE Remote IOs Field Devices FF-H1 P L Plant P L P L FF-H1 Linking Device Gateway O

Strona 24 - Butene Plant

© 1994 – 2011 Fieldbus Foundation 7 © ABB July 17, 2012 | 7  232 subscribers per link T R R R FO Seg. 4  32 subscr. Seg. 2  32 subscr. Seg. 3 Se

Strona 25 - Sinter Plant

© 1994 – 2011 Fieldbus Foundation 8 © ABB July 17, 2012 | 8 FOUNDATION HSE Operate Engineer Control OPC Server Ethernet TCP/IP For the use of passiv

Strona 26

© 1994 – 2011 Fieldbus Foundation 9 © ABB July 17, 2012 | 9 FieldBarrier*) LS  120 m Ltotal = LT+ ( LS) 1.900 m LT 1.900 m Field EEx e EEx ia For

Strona 27

© 1994 – 2011 Fieldbus Foundation 11 © ABB July 17, 2012 | 11 Operate Engineer Control Field Ethernet / IEEE 802 / FO FOUNDATION Fieldbus HSE Linkin

Komentarze do niniejszej Instrukcji

Brak uwag