CDA FW250 Instrukcja Użytkownika Strona 18

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 40
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 17
net DC
T M
e OutBack Power Technologies FLEXnet™ DC is the ultimate in DC System monitoring
devices. Our integrated networked communications make valuable, usable data available
from your system, viewable on an OutBack MATE communications device (screens
seen below), providing you with the answers you need concerning your systems health,
performance and eciency. e FLEXnet DC provides real state-of-charge (S.O.C.)
information about the life and state of your battery bank.
FN-DC Specications
Battery Voltage Input Range 8.0 to 80.0 Volts DC
Battery Voltage Resolution 0.1 Volts DC
Number of Current Channels One to Three (each can be a Source or Load)
Current Range (Each Channel) -1000.0 amps to +1000.0 amps DC
Current Resolution 0.1 amps DC
State of Charge Display 0 to 100% (1% increments)
Aux Relay Configuration SPST, Magnetic Latching Relay
Aux Relay Max Rating 5 amps @ 30 Volts DC
Current Shunt Type (order separately) 500 Amp / 50mv
Display Primary OutBack Power MATE or MATE2 4 x 20 LCD, or MATE3
graphical display
Secondary Five LED Indicators on front of FLEXnet DC
Battery AH Capacity Range 100 to 10,000 amp Hours
Data Logging Memory Most recent 128 Days
Programmable AUX Relay Settings Battery Volts Adjustable from 8.0 to 80.0 VDC
State of Charge Adjustable from 0 to 100%
Time Delay Adjustable from 0 to 240 Minutes
Accuracy 0.5% of Reading +/- 2 Least Signicant Digits per channel
Operating Temperature Range 0 - 50
º
C
Mounting 3/4” Panel Mount Breaker Slot or Surface Mount
Warranty Standard 5 year
Weight Unit 5 oz. (.14kg)
Shipping 2 lbs. (.90kg)
Dimensions (H x W x L) Unit 0.74 x 3.72 x 6.60” (1.88 x 9.45 x 16.75 cm)
Shipping 2.13 x 9 x 11.5” (5.4 x 22.86 x 29.21 cm)
18
Battery Status Screen-
Easily see your systems current
condition with this at-a-glance display. is screen shows an
easy-to-interpret “fuel gauge” style status bar, current state of
charge and whether you are currently charging or discharging
your batteries. is is useful for those system owners who want a
way to quickly understand the current state of their battery bank.
Now Summary Screen-
Monitor the amount of power your
system is currently producing and consuming as well as the
amount of power going IN and OUT of your battery bank. is
screen also displays your battery banks voltage and current state
of charge, providing you with real-time production monitoring of
DC sources, such as a solar array or small wind turbine, as well as
consumption by loads.
Today Summary Screen-
Monitor the cumulative energy your system has produced and
consumed as well as the total amount of energy that has gone to charging your batteries today. is
screen also displays today’s lowest state of charge and allows you to see how your overall system
production compares to system consumption.
History Summary Screen
-Review historical energy production/consumption data for the most
recent 128 days, including the minimum battery state of charge reached for each day. is screen
can be used to watch power system production and consumption trends.
DC -1DAY min SOC 88%
In 12AH 0.71kWH
Out 25AH 1.32kWH
Bat -13AH -0.6kWH
DC TODAY minSOC 95%
In 14AH 0.81kWH
Out 11AH 0.57kWH
Bat 3AH 0.24kWH
Ba tte ry D isc har gin g
St ate of Cha rge 9 6%
E F
* Specications subject to change without notice.
System Monitoring Device
Przeglądanie stron 17
1 2 ... 13 14 15 16 17 18 19 20 21 22 23 ... 39 40

Komentarze do niniejszej Instrukcji

Brak uwag