8
Inverter/Charger
GS Load Center
Model: GSLC*
Description: AC and DC enclosure for use with the Radian Series Inverter/Charger. Recommended for custom-built systems,
and for multiple Radian inverter systems (one GSLC per inverter).
Includes: Ground bus bar, 500 amp DC shunt assembly, neutral bus bar, two PV (positive) bus bars, inverter power bus bars,
FW-BBUS and enclosure mounting hardware
Unit Weight = 26 lbs (11.8 kg) Shipping Weight = 34 lbs (15.4 kg)
Model: GSLC 175-120/240*
Description: GS Load Center factory prepared for AC Applications, with inverter DC overcurrent protection and disconnect,
dual AC inputs, and 120/240 Vac maintenance bypass assembly. Recommended for systems which have a single Radian
inverter and an AC source, but can be customized in other ways.
Includes: Ground bus bar, 500 amp DC shunt assembly, neutral bus bar, two PV (positive) bus bars, inverter power bus bars,
FW-BBUS, two 175A panel mount breakers, four 50A 120/240VAC double pole panel mount breakers, sliding bypass interlock,
AC wiring, and enclosure mounting hardware
Unit Weight = 37 lbs (16.8 kg) Shipping Weight = 45 lbs (20.4 kg)
Model: GSLC 175-PV-120/240*
Description: GS Load Center factory prepared for PV and AC Applications, with inverter DC overcurrent protection and
disconnect, dual AC inputs, 120/240 Vac maintenance bypass assembly, PV GFDI, and two PV array inputs, FLEXnet DC battery
monitor and three shunts. “Plug and play” for systems which have a single Radian inverter and two charge controllers and
need battery monitoring.
Includes: Ground bus bar, three 500 amp DC shunts and shunt bus bar, neutral bus bar, two PV (positive) bus bars, inverter
power bus bars, FW-BBUS, two 175A panel mount breakers, four 50A 120/240VAC double pole panel mount breakers, sliding
bypass interlock, two 80A array disconnects, dual pole GFDI and controller disconnects, FLEXnet DC, AC and DC wiring and
enclosure mounting hardware
Unit Weight = 38 lbs (17.2 kg) Shipping Weight = 47 lbs (21.3 kg)
*For all GSLC models the Unit Dimensions (HxWxD) are 17” x 16” x 8.5” (43.2cm x 40.6cm x 12.6cm) and the Shipping
Dimensions (HxWxL) are 23.25” x 20.5” x 13.25” (59.1cm x 52.1cm x 33.7cm).
Additional Accessories
Model Description
GS-SBUS Shunt bus to connect three shunts together within the GSLC
STBB-BLACK Bus bar with black insulators and mounting screws
STBB-RED Bus bar with red insulators and mounting screws
STBB-WHITE Bus bar with white insulators and mounting screws
Panel Mount Breaker Model Current Rating Voltage Rating Branch Circuit Terminals Width
PNL-50D-AC-120/240 50 amp (each of 2 poles) 120/240VAC 5k AIC 1/4” stud 1.5” (39 mm)
GS-IOB-120/240VAC Input-Output Bypass Assembly
Description: Field-installable kit for bypassing the AC input to the AC output for inverter maintenance or installation. Also
provides overcurrent protection. Intended for use with single inverter installations.
Includes: Four 50A 120/240VAC double pole panel mount breakers, sliding bypass interlock plate, three STBB-BLACK and
three STBB-RED terminal bus bars, wire and hardware kit.
System Rating Bypass Breaker Input Breakers Output Breaker
120/240 VAC @ 50 amps Dual pole @ 50 amps Two dual pole @ 50 amps Dual pole @ 50 amps